• Users Online: 237
  • Home
  • Print this page
  • Email this page
Home About us Editorial board Ahead of print Current issue Search Archives Submit article Instructions Subscribe Contacts Login 
RESEARCH ARTICLE
Year : 2014  |  Volume : 3  |  Issue : 2  |  Page : 184-192

Reversed phase high performance liquid chromatographic method for simultaneous estimation of pregabalin and aceclofenac in tablet formulation (Acenac-N)


1 Department of Pharmaceutical chemistry and PG studies, M.E.S. College of Pharmacy, Sonai, Tq-Newasa, Dist-Ahmednagar, Maharashtra, -414105, India
2 Department of Quality assurance technique and PG studies, M.E.S. College of Pharmacy, Sonai, Tq-Newasa, Dist-Ahmednagar, Maharashtra, -414105, India

Correspondence Address:
Shantaram Gajanan Khanage
Department of Pharmaceutical chemistry and PG studies, M.E.S. College of Pharmacy, Sonai, Tq-Newasa, Dist-Ahmednagar, Maharashtra
India
Login to access the Email id

Source of Support: None, Conflict of Interest: None


Rights and PermissionsRights and Permissions

Pregabalin (PRG) is a new antiepileptic drug and Aceclofenac (ACE) is a potent non-steroidal anti-inflammatory drug. These drugs in combination are used for treatment of partial seizures and neuropathic pains. A simple and precise assay method by RP-HPLC was developed and validated for estimation of PRG and ACE in Acenac-N tablet. Analyses of commercial tablet, Acenac-N were performed using JASCO Isocratic HPLC system at 248 nm on a reverse phase column HiQ sil C18HS (4.6 × 250 mm, 5μm), a mobile phase; methanol: phosphate buffer (70:30 v/v, PH 3). The validation aspects were selectivity, linearity, precision, accuracy and quantification limit. Linearity, 5-25 μg/mL for PRG and ACE respectively, provided determination coefficients (R2) of 0.998 and 0.994 respectively, for PRG and ACE and proved precise since the RSD% was less than 2%. The recoveries obtained ranged from 99.10% to 100.90% for both of the drugs with RSD% less than 2%. The LOD for PRG and ACE was found to be 0.270 μg/mL and 0.039 μg/mL respectively. The LOQ was found at 0.818 μg/mL and 0.120 μg/mL respectively for PRG and ACE. In this study, the optimization of mobile phase, flow rate, injection volume and wavelength were achieved. The retention time for PRG and ACE was 3.241 and 6.581 min respectively. Drug content of the Acenac-N tablet was found to be 99.53% and 100.12% respectively for PRG and ACE. The method was validated as per the ICH guidelines. This method is precise, accurate and easy to analysis PRG and ACE in tablets.


[PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed1714    
    Printed101    
    Emailed0    
    PDF Downloaded241    
    Comments [Add]    

Recommend this journal